Kiran adds one sensor
Filler 2 keeps overfilling bottles. Kiran, the plant engineer, fits a level sensor on it and adds it to the machine’s controller.
Twenty minutes, and the machine knows its own level.
When a sensor is added or a machine is replaced, engineers update the factory computer, the floor screens and the online dashboard by hand, one by one. LineSync does it for them. The engineer approves once, and LineSync checks that every screen shows the right reading.
One small change on one machine: the way it goes today, and the way it goes with LineSync.
Filler 2 keeps overfilling bottles. Kiran, the plant engineer, fits a level sensor on it and adds it to the machine’s controller.
Twenty minutes, and the machine knows its own level.
The machine knows about the sensor. Nothing else does. Kiran has to add it by hand to the factory computer that collects readings, to the screens on the shop floor, and to the online dashboard the managers see.
A breakdown pulls him away. On Friday the floor screen still shows a blank, and the dashboard has no history. One sensor now has four different names.
Fill2_LvlTuesdayL1.Filler2.LevelWednesdayFiller 2 levelBlank on Fridayline1/filler2/levelNo historyA plant makes changes like this every week: a sensor added, a setting renamed, a controller replaced.
Take 20 changes a month, each typed into 4 systems, 20 minutes each. That is 320 hours a year, or 40 working days of one engineer, spent typing the same thing again. Every entry typed by hand is also a chance for a wrong name or a blank screen.
40 working days a year of one engineer, for an example plant
Source: survey of more than 600 US manufacturing leaders, L2L Manufacturing Data Paradox Report, 2026.
LineSync notices the new sensor in the controller by itself. It prepares the entry for the factory computer, the floor screens and the online dashboard, with matching names and units.
Kiran looks at one preview and approves once, with his password. LineSync updates all three, then reads each one back to confirm that every screen shows the same live value.
Sensor added to the machine controller
KiranNew sensor noticed. 3 updates prepared
LineSyncPreview checked and approved
KiranFactory computer, floor screens and dashboard updated. Readings match
LineSyncThe operators see the level on their screen the same morning. The managers’ dashboard has the full history from the first reading. Every change is on record, and the newest ones can be undone.
Kiran gets those 40 days back for the machines.
Three days is this story’s example. LineSync’s checks were tested on 1,756 signal hours of recordings from real test rigs, with no false alarms.
Pick a change that happens every week in a real factory. Then switch between how it is done today and how it is done with LineSync.
Pick a change
The same story in engineering terms: what happens to each system, what LineSync connects to, and how every change is approved, checked and undone.
LineSync reads every sensor every few seconds and learns how each one normally behaves. When a reading starts behaving oddly, it tells you in one plain sentence, with the reason.
Normal process changes, such as a start, a stop or a new steady level, are recognised as normal. A finding clears by itself when the readings recover.
Your engineers approve every change, and the factory keeps running while LineSync works.
LineSync reads from controllers, meters and machines. Controller logic stays with your engineers.
Every change waits for an engineer to approve it with their password. Anything uncertain is ticked on its own.
Before applying, it confirms the plant matches the preview. Afterwards it reads every layer back and checks the live readings.
If any product refuses a change, the others are returned to how they were and checked again.
An interrupted change holds further changes until every layer has been read and the state is clear.
Recent changes can be reversed one by one. Edits your team made by hand are kept unless you choose to replace them.
If the internet or the cloud is down, readings wait at the plant and arrive later with their original times.
Who approved what, when and on what evidence, kept so that any alteration shows. Plant data stays where it is today unless you switch on the optional hosted assistant.
LineSync connects to the machines, computers and software your factory runs today. For your engineers, here is the list.
Read by LineSync.
Updated automatically.
Ignition and FUXA update automatically. For the others, LineSync prepares an import file for the engineer to load.
Updated automatically, with live readings.
Other controller brands and platforms are added on request, one connector each.
Our plant makes about changes a month on the line: sensors added, signals renamed, controllers replaced. Each one is entered into systems, at around minutes in each.
Change any number to see your own plant.
of engineer time a year goes into entering the same changes again.
With LineSync each change is approved once, and every layer is checked live.
LineSync first checks every connection and login at the plant and reports, in plain language, anything that needs attention. Each connection is then tried in a separate test area, away from anything the plant uses.
Next it runs in watch mode for as long as you like. It reads everything and shows the changes it would have proposed. A pilot report then shows what it found, controller by controller, and your team decides when it goes live.
The behaviour checks were tested on public recordings of real test rigs, with every signal name removed. Across 1,756 signal hours of normal running they raised no false alarms. Our first plant pilots are starting now.
Tell us which controllers, gateway, floor screens and cloud your plant runs. We will tell you how LineSync fits and plan a pilot on one line.